Fluke 101 Basic Digital Multimeter

  • Basic dc accuracy 0.5%
  • CAT III 600 V safety rated
  • Diode and continuity test with buzzer
  • Small lightweight design for one-handed use
  • Rugged, durable design
  • Automatic shutdown
  • Battery is easy to replace

Fluke i400E AC Current Clamp

  • Compatible with most Fluke multimeters or mV ac measurement tools with these features:
    • 400 mV ac range
    • 19.05 mm banana jack inputs
    • Input accuracy of 2 % or greater to take full advantage of the accuracy of the product
    • Input impedance of >1 M?
  • 1 mV/A ac output guarantees easy current readings on you meter
  • CAT III 600 V safety rating
  • Specially designed to offer maximum utility in a very compact shape
  • Take accurate current readings

Tổng quan sản phẩm: Fluke 101 Digital Multimeter/i400E Clamp Kit

Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians. This small, lightweight multimeter fits comfortably in your hand but is rugged enough to withstand daily use for years to come. When it comes to professional-grade affordable multimeters, the Fluke 101 digital multimeter is your best choice.

The Fluke i400E AC Current Clamp is an ideal tool to extend current measurement. It is designed to work with the new Fluke 101, 106 and 107 palm sized digital multimeters, as well as most Fluke multimeters or other voltage measurement tools that accepts 19.05 mm shrouded banana plugs and has mV ac measurement functionality.

Thông số kỹ thuật: Fluke 101 Digital Multimeter/i400E Clamp Kit

Fluke 101 Basic Digital Multimeter

Electrical specifications
V AC (40-500Hz) Range 600.0 mV
6.000 V
60.00 V
600.0 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy 3.0% ±3 digit
1.0% ±3 digit
V DC Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy 0.5% ±3 digit
Resistance Ohms Range 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy 0.5% ±3 digit
0.5% ±2 digit
0.5% ±2 digit
0.5% ±2 digit
0.5% ±2 digit
1.5% ±3 digit
Capacitance Range 50.00 nF
500.0 nF
5.000 µF
50.00 µF
100.0 µF
Resolution 0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Frequency
(10 Hz – 100 kHz)
Range 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty cycle Range 0.1% to 99.9%
Resolution 0.1%
General specifications
CAT rating CAT III 600 V
V AC range 600.0 V
V DC range 600.0 V
Ohms range 40.00 MΩ
Auto shutoff Y
Continuity Y
Capacitor 100.0 µF
Frequency 100.0 kHz
Hold No
Duty cycle Yes
Size 130 x 65 x 27mm
Weight 160 g
Battery Two AAA
Warranty 1 year
Environmental specifications
Operating temperature 0 °C to +40 °C
Storage temperature -30 °C to +60 °C
Operating humidity Non condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without condensation)
Operating humidity, 40 MΩ 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating altitude 2,000 meters
Storage altitude 12,000 meters
IP rating IP 40 per IEC 60529
Vibration requirements MIL-PRF-28800F, Class 2
Drop test requirements -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMC Must meet all applicable requirements in
IEC/EN 61326-1
Absorption/corrosion Per Fluke SOP 39.1
Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC

Fluke i400E AC Current Clamp

Electrical specifications
AC current range

1 A to 400 A

Output signal 1 mV/A ac
Accuracy 2.0% ±5 digits (45 Hz to 65 Hz)
2.5% ±5 digits (65 Hz to 400 Hz)
Typical bandwith 5 Hz to 20 kHz
Working voltage 600 V ac rms, in compliance with IEC 61010-1 and IEC 61010-2-030
Load impedance 1 A to 400 A
Maximum non-destructive current 600 A
Jaw inner diameter 30 mm
Maximum wire size 600 MCM
Standard plugs 19.04 mm dual banana plugs
Safety specifications
Category rating IEC 61010-1 and IEC 61010-2-030/IEC 61010-2-031 and
IEC 61010-2-032: 600 V CAT III
Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
General specifications
Output cable length 1 m
Operating temperature -10 °C to +50 °C
Storage temperature -30 ºC to +60 ºC
Relative humidity ≤90% at 10 °C to 530 °C
≤75% at 30 °C to 540 °C
≤45% at 40 °C to 50 °C
IP rating IEC 60529: IP30 when jaw closed
Temperature coefficients Add 0.1 x specified accuracy for each °C above 28°C or below 18 °C.
Operating altitude 2,000 meters
Storage altitude 12,000 meters
Vibration requirements MIL-PRF-28800F, Class 2
Drop test requirements -10 °C, 1m, 6 sides, oak wood
Jaw impact test requirements Follow EN/IEC 61010-2-032:2012
EMI, RFI, EMC IEC/EN 61326-1
Dimensions (H x W x D) 146 x 62 x 34 mm
Weight 150 g

Model: Fluke 101 Digital Multimeter/i400E Clamp Kit

Fluke 101 Kit

Hãy mua ngay

Includes:

  • Fluke 101 Basic Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • Two AAA Batteries (Installed)
  • Smart Strap
Fluke 101/i400E Kit

Hãy mua ngay

Includes:

  • Fluke 101 Basic Digital Multimeter
  • Fluke i400E AC Current Clamp
  • Tl75 Hard Point Test Lead Set