Fluke Ti200 Thermal Camera
Detailed Specifications |
Temperature |
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +650 °C
(-4 °F to +1202 °F) |
Temperature measurement accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction |
Yes (by number and table) |
On-screen reflected background temperature compensation |
Yes |
On-screen transmission correction |
Yes |
Imaging Performance |
Image capture frequency |
9 Hz refresh rate or 60 Hz refresh rate depending upon model variation |
Detector type |
Focal Plane Array, uncooled microbolometer, 200 X 150 pixels |
Thermal sensitivity (NETD) |
≤ 0.075 °C at 30 °C target temp (75 mK) |
Total pixels |
30,000 |
Infrared spectral band |
7.5 μm to 14 μm (long wave) |
Visual (visible light) camera |
Industrial performance 5.0 megapixel |
Standard Infrared Lens Type |
Field of view |
24 ° x 17 ° |
Spatial resolution (IFOV) |
2.09 mRad |
Minimum focus distance |
15 cm (approx. 6 in) |
Optional Telephoto Infrared Lens Type |
Field of view |
12 ° x 9 ° |
Spatial resolution (IFOV) |
1.05 mRad |
Minimum focus distance |
45 cm (approx. 18 in) |
Optional Wide-Angle Infrared Lens Type |
Field of view |
46 ° x 34 ° |
Spatial resolution (IFOV) |
4.19 mRad |
Minimum focus distance |
15 cm (approx. 6 in) |
Focus Mechanism |
LaserSharp™ Auto Focus system |
Yes |
Advanced manual focus |
Yes |
Image Presentation |
Palettes |
Standard |
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast™ |
Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
Level and span |
Smooth auto-scaling and manual scaling of level and span |
Fast auto toggle between manual and auto modes |
Yes |
Fast auto-rescale in manual mode |
Yes |
Minimum span (in manual mode) |
2.0 °C (3.6 °F) |
Minimum span (in auto mode) |
3.0 °C (5.4 °F) |
IR-Fusion® Information |
Picture-in-Picture (PIP) |
Yes |
Full screen infrared |
Yes |
AutoBlend™ mode |
Yes |
Color alarms (temperature alarms) |
High-temperature , low-temperature, and isotherm (user-selectable) |
Image Capture and Data Storage |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
Storage medium |
Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection |
File formats |
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) |
No analysis software required for non-radiometric (.bmp and jpg) files |
Export file formats w/SmartView® software |
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Memory review |
Thumbnail view navigation and review selection |
Other Time-Saving and Productivity Features |
Voice annotation |
60 seconds maximum recording time per image; reviewable playback on imager |
IR-PhotoNotes™ |
Yes |
Wi-Fi connectivity |
Yes, to PC, iPhone®, iPad® and WiFi to LAN* |
Text annotation* |
Yes |
Video recording* |
Standard and radiometric |
Streaming video |
Via USB to PC and HDMI to HDMI compatible screen |
Fluke Connect® compatible |
Yes (where available) |
Auto capture (temperature and interval)* |
Yes |
Remote control and operation (for special and advanced applications) |
No |
General Specifications |
Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity |
10 % to 95 % non-condensing |
Ruggedized touchscreen display (capacitive) |
8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
Controls and adjustments |
User selectable temperature scale (°C/°F) |
Language selection |
Time/Date set |
Emissivity selection |
Reflected background temperature compensation |
Transmission correction |
User selectable hot spot and cold spot, and center point on the image |
Expandable-contractable Measurement Box with MIN-AVG-MAX temp |
Color alarms |
User selectable backlight setting graphical information display preference |
Graphical information display preference |
Software |
SmartView® and SmartView Mobile App - full analysis and reporting software included |
Batteries |
Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models |
Battery life |
Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage) |
Battery charge time |
2.5 hours to full charge |
AC battery charging |
Two-bay AC battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models |
AC operation |
AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. |
Power saving |
User selectable sleep and power off modes |
Safety standards |
UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010) |
Electromagnetic compatibility |
EN 61326-1:2006 IEC 61326-1:2005 |
C Tick |
IEC/EN 61326-1 |
US FCC |
CFR 47, Part 15 Subpart B Class B |
Vibration |
0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 |
Shock |
25 g, IEC 68-2-29 |
Drop |
Engineered to withstand 2 meter (6.5 feet) with standard lens |
Size (H x W x L) |
27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) |
Weight (battery included) |
1.04 Kg (2.3 lb) |
Enclosure rating |
IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty |
Two-years (standard), extended warranties are available. |
Recommended calibration cycle |
Two-years (assumes normal operation and normal aging) |
Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
*Coming soon via firmware update. Users notified via SmartView software when available.
Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications |
AC Voltage |
Range 1 |
Resolution |
Accuracy 2 3 4 |
45 Hz to 500 Hz |
500 Hz to 1 kHz |
600.0 mV |
0.1 mV |
1.0 % + 3 |
2.0 % + 3 |
6.000 V |
0.001 V |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
Function |
Range |
Resolution |
Accuracy |
mV |
600.0 mV |
0.1 mV |
0.09 % + 2 |
V |
6.000 V |
0.001 V |
0.09 % + 2 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
0.15 % + 2 |
Ω |
600 Ω |
1 Ω |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
Ω |
600.0 Ω |
0.1 Ω |
0.5 % + 2 |
6.000 kΩ |
0.001 kΩ |
0.5 % + 1 |
60.00 kΩ |
0.01 kΩ |
60.00 kΩ |
0.1 kΩ |
600.0 kΩ |
0.001 MΩ |
50.00 MΩ |
0.01 MΩ |
1.5 % + 3 |
Diode test |
2.000 V |
0.001 V |
1 % + 2 |
µF |
1000 nF |
1 nF |
1.2 % + 2 |
10.00 μF |
0.01 μF |
100.0 μF |
0.1 μF |
9999 μF1 |
1 μF |
10 % typical |
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. |
AC and DC Current |
Function |
Range 1 |
Resolution |
Accuracy |
mA AC
(45 Hz to 1 kHz) |
60.00 mA |
0.01 mA |
1.5 % + 3 |
400.0 mA 3 |
0.1 mA |
mA DC 2 |
60.00 mA |
0.01 mA |
0.5 % + 3 |
400.0 mA 3 |
0.1 mA |
1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload. |
Frequency |
Range |
Resolution |
Accuracy 1 |
99.99 Hz |
0.01 Hz |
0.1 % + 1 |
999.9 Hz |
0.1 Hz |
9.999 kHz |
0.001 kHz |
99.99 kHz |
0.01 kHz |
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
Input Characteristics |
Function |
Overload
protection |
Input impedance
(nominal) |
Common mode rejection ratio (1 kΩ unbalance) |
Normal mode rejection |
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 60 dB, DC to 60 Hz |
|
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
Open circuit test voltage |
Full scale voltage |
Typical short circuit current |
To 6 MΩ |
50 MΩ |
|
1100 V RMS |
< 2.7 V DC |
< 0.7 V DC |
< 0.9 V DC |
< 350 mA |
|
1100 V RMS |
< 2.7 V DC |
2.000 V DC |
< 1.1 mA |
mA Function |
Overload Protection |
Fused, 44/100 A, 1000 V FAST Fuse |
Overload |
600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording Accuracy |
DC functions |
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions |
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications |
Maximum voltage between any terminal and earth ground |
1000 V DC or AC RMS |
Ω fuse protection from A inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) |
Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts |
Battery type |
Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life |
250 hours minimum |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature |
Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C |
Temperature coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity |
0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C) |
Altitude |
Operating: 2,000 m
Storage: 12,000 m |
Electromagnetic compatibility
EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010 |
Certifications |
CSA, FCC, CE |
Ingress Protection (IP) rating |
IP54 |
Pollution degree |
2 |
Size (H x W x L) |
4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in) |
Weight |
340 g (12 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools
Fluke a3001 FC Wireless iFlex AC Current Module
Specifications |
Range |
0.5 A to 2500 A AC |
Resolution |
0.1 A |
Accuracy |
3 % ± 5 digits (5 Hz to 500 Hz) |
Crest factor (50 Hz/60 Hz) |
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
LCD w/backlight |
3½ digits |
Log rate/interval |
1 sec minimum/adjustable by PC or front panel |
Battery type |
2 AA, NEDA 15 A, IEC LR6 |
Battery life |
400 hours |
Memory |
Record up to 65,000 readings |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
Operating humidity |
90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
Altitude |
Operating: 2,000 m
Storage: 12,000 m |
EMC |
EN 61326-1:2006 |
Safety compliance |
IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition |
Safety rating |
CAT IV 600 V, CAT III 1000 V |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Pollution degree |
2 |
Jaw opening |
25.4 cm (10 in) coil |
Size (HxWxD) |
16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight |
.22 kg (8 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools
|