Select your country site

Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit

Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit is rated 1.1 out of 5 by 9.
  • y_2024, m_9, d_19, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_8
  • loc_en_US, sid_3840950370356, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 65.24ms
  • REVIEWS, PRODUCT
  • Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit
  • SS: 3540 FC Three-Phase Power Monitor 2
  • SS: 3540 FC Three-Phase Power Monitor 3

Key Features

  • Measures:
    • Single, split, or three phase loads
    • Voltage, current, and frequency
    • Active power, non-active power, and power factor
    • Total harmonic distortion
  • Wireless data collection or internal memory sufficient for 1 week with 1 second data intervals
  • Remotely monitor real-time and historical power variable data
  • Visualize data with software trending, graphing, and timeboxing
  • Auto-generated alarms when power variables deviate from pre-set thresholds
  • Power options: Battery, power supply, or power from the measurement line
  • Size: (W x H x D) 7.8 in. x 6.6 in. x 2.2 in.
  • IP Rating: IP 50; IEC 60529

Product overview: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit

The Fluke 3540 FC monitors equipment for changes in key electrical variables. Current, voltage, frequency, and energy consumption fluctuate when machinery experiences excess load. Screen assets for performance or premature wear using the non-invasive 3540 FC.

  • Portable device offers scalable, remote power monitoring solution
  • View power measurements from a safe distance
  • Wirelessly collect real-time power values
  • Make data-driven decisions

See "Model" tab for kit options.

What's in the box:

  • Fluke 3540 FC Three-Phase Power Monitor
  • Voltage Test Lead, 3-phase + N
  • (4 sets) Dolphin Clips, Black
  • (3) i173x-flex1500 iFlex Current Probe, 30.5 cm (12 in)
  • Set of color-coded Wire Clips
  • Mains Power Cable
  • (2 sets) test leads with stackable plugs, 10 cm (3.9 in)
  • (2 sets) test leads with stackable plugs, 1.5 m (6.6 ft)
  • DC Power Cable
  • Input Connector Decal
  • WiFi to USB Adapter
  • Magnetic Hanging Kit

Specifications: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit

General specifications
Color LCD display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty 3540 FC and built-in power supply 2 years (battery not included)
Accessories 1 year
Calibration cycle 2 years
Dimensions (WxHxD 3540 FC 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)
Detachable power supply 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)
3540 FC with power supply attached 19.8 cmx 16.7 x 9 cm (7.8 x 6.6 x 4.0 in)
Weight 3540 FC 1.1kg (2.5 lb)
Power supply
Tamper protection Kensington lock
Environmental specifications
Operating temperature 0 °C to +45 °C (+32 °F to +113 °F)
Storage temperature <20 °C to +60 °C (-4 °C to +140 °F), with battery: -20 °C to +50 °C (-4 °F to +122 °F)
Operating humidity <10 °C (<50 °F) non condensing
+10 °C to +30 °C (+50 °F to +86 °F) ≤95 %
+30 °C to +40 °C (+86 °F to +104 °F) ≤75 %
+40 °C to +45 °C (+104 °F to +113 °F) ≤45 %
Operating altitude 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000 m (39,000 ft)
IP Rating IEC 60529:IP50, in connected condition with protection caps in place
Vibration MIL-T-28800E, Type 3, Class III, Style B
Safety
IEC 61010-1 IEC mains input Overvoltage Category II, Pollution Degree 2
Voltage terminals Overvoltage Category IV, Pollution Degree 2
Electromagnetic compatibility (EMC)
International IEC 61326-1: Industrial
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter
Frequency range 2412 MHz to 2462 MHz
Output power <100 mW
Electrical specifications
Single and three-phase topologies
Wiring configurations 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Voltage inputs
Number of inputs 4 (3 phases and neutral)
Maximum input voltage 1000 Vrms (1700 Vpk) phase to neutral
Input impedance 10 MΩ each phase to neutral
Bandwidth 42.5 Hz to 3.5 kHz
Scaling 1:1, variable
Current inputs
Number of inputs 3, mode selected automatically for attached sensor
Current sensor output voltage Clamp 500 mVrms / 50 mVrms; CF 2.8
Rogowski coil 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Bandwidth (-3 dB) 42.5 Hz to 3.5 kHz
Scaling 1:1 and variable
Data acquisition
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60Hz, synchronized to mains frequency
Input signal frequency Mains 50/60 Hz (42.5 to 69 Hz)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.
Measured parameters Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
Averaging interval 1 s
Total harmonic distortion THD for voltage and current is calculated on 25 harmonics
Calculated min/max values times
Voltage Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ)
Current Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
Power 200 ms
Interfaces
USB-A Firmware updates, max. supply current: 120 mA
WiFi
Supported modes Direct connection and connection to infrastructure
Security WPA2-AES with pre-shared key
Power supply
Voltage range Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
Mains power Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Standby power <0.3 W only when powered using IEC 60320 input
Efficiency ≥68.2 % (in accordance with energy efficiency regulations)
Mains frequency 50/60 Hz ±15 %
Battery power Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Up to 4 hr (up to 5.5 hr in energy saving mode)
Charging time <6 hr

Models: Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit

FLUKE 3540 FC KIT

Fluke 3540 FC Three-Phase Power Monitor and Condition Monitoring Kit


Includes:

  • 1 Fluke 3540 FC Three-Phase Power Monitor
  • Voltage Test Lead, 3-phase + N
  • 4x Dolphin Clips, Black
  • 3x i173x-flex1500 iFlex Current Probe, 30.5 cm (12 in)
  • Set of color-coded Wire Clips
  • Mains Power Cable
  • Set of 2 test leads with stackable plugs, 10 cm (3.9 in)
  • Set of 2 test leads with stackable plugs, 1.5 m (6.6 ft)
  • DC Power Cable
  • Input Connector Decal (see Figure 5)
  • WiFi to USB Adapter
  • Magnet Hanger Kit

Purchase comes with Fluke Connect Condition Monitoring software.

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 31.36ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, , 31.39ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; Content Type "questions" is not supported by getReviews().;
Please enable cookies to view product reviews.