Select your country/region site

Fluke 1652C Multifunction Installation Tester

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 68.98ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 1652C Multifunction Installation Tester
Discontinued

Key features

Safer, easier installation testing.

The 1652C Installation Tester verify the safety of electrical installations in domestic, commercial and industrial applications. It can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364, HD 384 and all relevant local standards.

Faster

  • Two measurements at once and a dual display. PEFC/PSC and loop impedance are measured and displayed in parallel, saves you more than 50% of test time compared to other loop testers.
  • Additional new high current loop mode. Faster measurements compared to loop tests with non-trip mode for RCD’s.
  • Unique zero adapter for fast, always reliable and accurate test lead and mains cord compensation.
  • Fast voltage measurement between L-N, L-PE and N-PE using the mains cord. No need to change measurement connections.

Safer

  • Earth Volt Touchpad detects raised earth voltages 50 V, indicating potential dangerous situations.
  • with the SureGrip™ test leads and clips which gives the user a comfortable, reliable grip.

Easy

  • Rotary dial knob indicates clear which function is selected, all functionalities on one spot and no complex multi level menus.
  • Large display with backlight, clear symbols and exceptionally wide viewing angle for easy and safe readings.
  • PASS/FAIL indication for RCD test results.
  • Variable RCD current mode for customized settings.
  • Extended documentation mode (UK only)

Rugged & lightweight Withstands a drop of 1 meter. Compact, lightweight (less than 1.3 kg) and padded neck-strap to free your hands for all day testing.

1650B Kit Complete kit
All 1650 models are equipped with detachable leads that can be replaced in case of damage or loss. A durable hard case will protect your instrument in tough field conditions.

Slim probe design with test button
Keeps your eyes on the panel while probing hard to reach points. This remote probe is powered by the tester so always operable (does not require additional batteries).

Zero Adapter

For easy, always reliable and accurate compensation of test leads and mains cords. This adapter can be used for all different kind of mains plugs as well as test accessories like probes, alligator clips etc.
This product is discontinued or reclassified

Product overview: Fluke 1652C Multifunction Installation Tester

Extra functionality, faster testing, and as rugged as ever

The 1652C Installation Tester builds upon the rugged reputation of the earlier 1650 Series, only it’s re-designed to meet your need for more productive test tools.

This installation tester offers the following new capabilities:

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Extended documentation mode (UK only)
Measurement functions Fluke 1652C Fluke 1653B Fluke 1654B
Voltage and frequency

Wiring polarity checker

Insulation resistance 250 V, 500 V, 1000 V 50 V, 100 V, 250 V,
500 V, 1000 V
50 V, 100 V, 250 V,
500 V, 1000 V
Continuity      
Loop and line resistance

Loop and line resistance-mΩ resolution    

PEFC/PSC (fault/short-circuit current)

RCD tripping time

RCD tripping current level

Ramp test

Automatic ROD test sequence

Test dc-sensitive RCDs (type A)

Test dc-sensitive RCDs (type B)    

Earth resistance  

Phase sequence indicator

Other features      
Self-test

EN 61557*/VDE 0413 compliant

Illuminated display

Live voltage indicator

Battery indicator and battery test function

Memory, interface      
Memory  

Extended memory    

Computer interface  

Time stamp (software enabled)  

Software (optional)  

Specifications: Fluke 1652C Multifunction Installation Tester

Specifications
AC voltage measurement Range 500 V
Resolution 0.1 V
Accuracy (50 - 60 Hz) ±(0.8% + 3 digits)
Input impedance 3.3 MΩ
Overload protection 660 Vrms
Continuity testing Range (autoranging) 20 Ω, 200 Ω, 2000 Ω
Resolution 0.01 Ω, 0.1 Ω, 1 Ω
Test current > 200 mA
Open circuit voltage > 4 V
Accuracy ±(1.5%+3 digits)
Insulation Resistance Measurement
Test voltage Fluke 1652C 250 - 500 - 1000 V
Fluke 1653B + 1654B 50 - 100 - 250 - 500 - 1000 V
Test voltage (50 V) Test current 1 mA @ 50 kΩ
Insulation range 10 kΩ - 50 мΩ
Resolution 0.01 мΩ
Accuracy ±(3% + 3 digits)
Test voltage (100 V) Test current 1 mA @ 100 kΩ
Range/Resolution 20 MΩ/0.01 MΩ / 100 MΩ/0.1 MΩ 
Accuracy ±(3% + 3 digits)
Test voltage ( 250 V) Test current 1 mA @ 250 kΩ
Range/Resolution 20 MΩ/0.01 MΩ /200 MΩ/0.1 MΩ 
Accuracy ±(1.5% + 3 digits)
Test voltage (500 V) Test current 1 mA @ 500 kΩ
Range/Resolution 20 MΩ/0.01 MΩ
Range/Resolution 200 MΩ/0.1 MΩ
Accuracy ±(1.5% + 3 digits)
Range/Resolution 500 MΩ/1 MΩ
Accuracy 10%
Test voltage (1000 V) Test current 1 mA @ 1 MΩ
Range/Resolution 20 MΩ/0.01 MΩ
Range/Resolution 200 MΩ/0.1 MΩ
Accuracy ±(1.5% + 3 digits)
Range/Resolution 500 MΩ/1 MΩ
Accuracy 10%
Auto discharge Discharge time constant, 0.5 second for C = 1 µF or less
Live circuit detection Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum capacitive load Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)
  Range 100 - 500 VAC (50/60 Hz)
Input connection Soft Key selection
Loop impedance Phase to earth
Line impedance Phase to neutral
Limit on consecutive tests Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
   
Range/Resolution (High Current) 20 Ω/0.001Ω (1mΩ) (Fluke 1654B)
Range/Resolution 20 Ω/0.01 Ω
Range/Resolution 200 Ω/0.1 Ω
Range/Resolution 2000 Ω/1 Ω
   
Accuracy (no Trip mode) ±(3% + 6 digits)
Accuracy (Hi Current mode) ±(2% + 4 digits)
Accuracy (Hi Current mode 1mΩ) ±(2% + 15 digits) (Fluke 1654B)
PFC, PSC Test Computation PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range 0 - 25 kA
Resolution (Ik < 1000 A) 1 A
Resolution (Ik >= 1000 A) 0.1 kA
Accuracy Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹ Fluke 1654B A, AC, B, B+, F, G/R, S
Fluke 1652C A, AC, F, G/R, S
Fluke 1653B A, AC, F, G/R, S
Tripping Time Test (ΔT)
Trip time accuracy  ±(1% Reading + 1 digit)
Multiplier: x ½  Current Settings 10, 30, 100, 300, 500, 1000 mA
Current Accuracy +0% - 10%
RCD Type ¹ G
Measurement Range 310 ms (Europe), 2000 ms (UK)
RCD Type ¹ S
Measurement Range 510 ms (Europe), 2000 ms (UK)
Multiplier: x 1 Current Settings 10, 30, 100, 300, 500, 1000 mA
Current Accuracy +10% - 0%
RCD Type ¹ G
Measurement Range 310 ms
RCD Type ¹ S
Measurement Range 510 ms
Multiplier: x 5 Current Settings 10, 30 mA
Current Accuracy ±10%
RCD Type ¹ G
Measurement Range 50 ms
RCD Type ¹ S
Measurement Range 160 ms
Tripping Current (ramp)
Current range 50% - 110% of RCD's rated current
Step Size 10% of IΔN
Dwell time (Type G) ¹ 300 ms / step
Dwell time (Type S) ¹ 500 ms / step
Trip current measurement zccuracy ±5%
Earth Resistance Test (RE) - Fluke 1653B + 1654B
Range/Resolution 200 Ω/0.1 Ω
Accuracy ±(2% + 5 digits)
Range/Resolution 2000 Ω/1 Ω
Accuracy ±(3.5% + 10 digits)
Frequency 128 Hz
Compliance voltage +25 V
Phase Sequence Indication
Icon Icon Phase Sequence indicator is active
Display of Phase Sequence Displays '1-2-3' in digital display field for correct sequence
Displays '3-2-1' for incorrect phase
Dashes in place of a number indicate a valid determination could not be made
¹ RCD Types
G General, no delay
S Time delay
A Responds to pulsed signal
AC Responds to AC
1654B 
Environmental Specifications
Operating temperature -10 °C to 40 °C
Humidity (without condensation) 10 to 30 °C 95%
30 to 40 °C 75%
Safety Specifications
Safety Rating EN 61010-I CAT III 500V, CAT IV 300V
Mechanical and General Specifications
Size (L x W x H) 10 x 25 x 12.5 cm
Weight 1.3 kg
Batteries Type AA: 6
Warranty 3 years
Battery type Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries

Models: Fluke 1652C Multifunction Installation Tester

Fluke 1652C
Fluke 1652C Multifunction Installation Tester

  • 6 AA Cell batteries
  • C1600 Hard carrying case
  • Zero Adapter
  • Mains test cord
  • TL165X/STD Standard Test Lead Set
  • Padded carrying strap
  • Quick reference guide
  • TP165X Remote control probe and lead¹
  • Users manual on CD-ROM
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 77.94ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, , 77.97ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; Content Type "questions" is not supported by getReviews().;
Please enable cookies to view product reviews.