Key features

The Ti400 offers:

  • Consistently in-focus images with the exclusive LaserSharp® Auto Focus system
  • See the crucial details needed to help clearly identify potential problems with precisely blended visual and infrared images – only with IR Fusion® technology with AutoBlend™ mode.
  • Fluke Connect® compatible - the largest network for wirelessly enabled tools
  • Faster communication with wireless image transfer directly to your PC, Apple® iPhone® or iPad®
  • High-temperature measurement up to 1200 °C
  • Ruggedized high resolution 640 x 480 capacitive touch screen for quick menu navigation
  • Capture additional digital images to show location or additional site details with IR-PhotoNotes™ Annotation System
  • More advanced display output options to get the details via streaming video to PC or high definition monitor (USB and HDMI)
  • Voice recording and annotation gets additional details saved with the image file
  • Optional interchangeable lenses for greater flexibility in additional applications
  • Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight for quick menu navigation
  • 5 MP industrial-performance digital camera for high definition image quality
  • Included SmartView® and SmartView Mobile App Analysis and Reporting Software

The 3000 FC Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000 V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap
This product is discontinued or reclassified

Product overview: Fluke Ti400 a3001 FC iFlex® Kit

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Learn more

See How It Works
Fluke Connect FAQs

The Ti400 Thermal Camera combined with the Fluke Connect® App and the a3001 FC iFlex module is a high performance cutting edge kit that helps you accurately troubleshoot issues and get you back online. Safely capture AC current measurements with your Fluke a3001 FC iFlex module from up to 20 meters away on the 3000 FC DMM, while simultaneously conducting an infrared inspection with your Ti400 thermal camera. Upload all your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

The Ti400 is one of only three thermal cameras in the Fluke portfolio equipped with LaserSharp® Auto Focus for consistently in-focus images. Every. Single. Time. Without an in-focus image, temperature measurements may be off by as much as 20 degrees, making it much easier to miss a potential problem. LaserSharp Auto Focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the equipment you are inspecting, then pull and release the trigger for a perfect in-focus image. Uptime or downtime. Your Results Matter.

Specifications: Fluke Ti400 a3001 FC iFlex® Kit

Fluke Ti400 Infrared Camera

Detailed Specifications
Temperature
Temperature measurement range (not calibrated below -10°C) -20°C to +1200°C
(-4°F to +2192°F)
Temperature measurement accuracy ±2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correction Yes (by number and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Imaging Performance
Image capture frequency 60 Hz refresh rate
Detector type Focal Plane Array, uncooled microbolometer, 320 x 240 pixels
Thermal sensitivity (NETD) ≤ 0.05°C at 30°C target temp (50 mK)
Total pixels 76,800
Infrared spectral band 7.5 μm to 14 μm (long wave)
Visual (visible light) camera Industrial performance 5.0 megapixel
Standard Infrared Lens Type
Field of view 24° x 17°
Spatial resolution (IFOV) 1.31 mRad
Minimum focus distance 15 cm (approx. 6 in)
Optional Telephoto Infrared Lens Type
Field of view 12° x 9°
Spatial resolution (IFOV) 0.65 mRad
Minimum focus distance 45 cm (approx. 18 in)
Optional Wide-Angle Infrared Lens Type
Field of view 46° x 34°
Spatial resolution (IFOV) 2.62 mRad
Minimum focus distance 15 cm (approx. 6 in)
Focus Mechanism
LaserSharp® Auto Focus system Yes
Advanced manual focus Yes
Image Presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0°C (3.6°F)
Minimum span (in auto mode) 3.0°C (5.4°F)
IR-Fusion® Information
Picture-in-Picture (PIP) Yes
Full screen infrared Yes
AutoBlend™ mode Yes
Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
Image Capture and Data Storage
Image capture, review, save mechanism One-handed image capture, review, and save capability
Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp and jpg) files
Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
Other Time-Saving and Productivity Features
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes™ Yes
Wi-Fi connectivity Yes, to PC, iPhone®, iPad® and WiFi to LAN1
Text annotation1 Yes
Video recording1 Standard and radiometric
Streaming video Via USB to PC and HDMI to HDMI compatible screen
Fluke Connect compatible Yes (where available)
Auto capture (temperature and interval)1 Yes
Remote control and operation (for special and advanced applications) Yes
General Specifications
Operating temperature -10°C to +50°C (14°F to 122°F)
Storage temperature -20°C to +50°C (-4°F to 122°F) without batteries
Relative humidity 10% to 95% non-condensing
Ruggedized touchscreen display (capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Controls and adjustments User selectable temperature scale (°C / °F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image
Expandable-contractable Measurement Box with MIN-AVG-MAX temp
Color alarms
User selectable backlight setting graphical information display preference
Graphical information display preference
Software SmartView® and SmartView Mobile App - full analysis and reporting software included
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
Battery life Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
AC operation AC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
Power saving User selectable sleep and power off modes
Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Subpart B Class B
Vibration 0.03 g2/Hz (3.8 grms), 2.5 g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
Size (H x W x L) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (battery included) 1.04 Kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available.
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
1. Coming soon via firmware update. Users notified via SmartView software when available.
 

Fluke 3000 FC Series Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mV Range / Resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / Resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / Resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 1.5% + 3
mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ Typical short circuit current
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools
 

Fluke a3001 FC Wireless iFlex AC Current Module

Specifications
Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/ backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Jaw opening 25.4 cm (10 in) coil
Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight .22 kg (8 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

Models: Fluke Ti400 a3001 FC iFlex® Kit

FLK-Ti400 60HZ/FCA
Fluke Ti400 a3001 FC iFlex® Kit

Buy it

Includes:

Ti400 Infrared Camera

  • AC power supply and battery pack charger (including mains adapters)
  • Two, rugged lithium ion smart battery packs
  • Micro SD memory card
  • USB cable
  • HDMI video cable
  • SmartView® software available via free download
  • Rugged, hard carrying case
  • Soft transport bag
  • Adjustable hand strap
  • Warranty registration card
  • International adapter set (9 Hz only)

3000 FC Series Wireless Multimeter

  • Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)
  • One (1) a3001 FC Module with two (2) AA batteries (installed)
  • One (1) iFlex 10"" coil
  • One (1) magnet/strap
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 65.54ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, , 65.56ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; Content Type "questions" is not supported by getReviews().;
Please enable cookies to view product reviews.

Manuals + resources: Fluke Ti400 a3001 FC iFlex® Kit