Key features

  • Automatic pressure generation and regulation to 300 psi
  • Configure procedures for pressure transmitters and switches
  • Measure, source, and simulate 4 to 20 mA signals
  • Troubleshoot and calibrate HART smart transmitters
  • Automatically document test results

Product overview: Fluke 729 Automatic Pressure Calibrator

Portable automatic pressure calibrator simplifies pressure calibration

The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pres­sure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment con­trol automatically stabilizes the pressure at the requested value.

The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.

Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.

Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.

With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.

What's in the box:

  • Fluke 729 Automatic Pressure Calibrator
  • Li-Ion battery charger and adapters
  • Quick-Connect pressure fitting, hose and adapter starter kit
  • (1 pair) Stackable test leads
  • (1 set) AC280 SureGrip™ hook clips
  • (1 set) AC175 alligator clips
  • (1 pair) TP220 test probes (red, black)
  • USB communication cable
  • TPAK ToolPak™ Magnetic Meter Hanger Carrying case with shoulder strap and accessories pouch
  • DPCTrack2™ trial calibration management software
  • Traceable certificate of calibration
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 729 Automatic Pressure Calibrator

Pressure specification*
One-year specification 0.02% of full scale
Control specification 0.005% full scale minimum
*See manual for detailed specifications

 

Model
729 30G
Psi range, resolution -12.0000 to 30.0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment No wireless communication
729 150G
Psi range, resolution -12.000 to 150.000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment No wireless communication
729 300G
Psi range, resolution -12.000 to 300.000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment No wireless communication
729 30G FC
Psi range, resolution -12.0000 to 30.0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment Wireless communication for Fluke Connect
729 150G FC
Psi range, resolution -12.000 to 150.000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment Wireless communication for Fluke Connect
729 300G FC
Psi range, resolution -12.000 to 300.000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment Wireless communication for Fluke Connect
729CN 200K
Psi range, resolution -12.0000 to 30.0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment For China, no wireless communication
729CN 1M
Psi range, resolution -12.000 to 150.000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment For China, no wireless communication
729CN 2M
Psi range, resolution -12.000 to 300.000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment For China, no wireless communication
729CN 200K FC
Psi range, resolution -12.0000 to 30.0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment For China, wireless communication for Fluke Connect
729CN 1M FC
Psi range, resolution -12.000 to 150.000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment For China, wireless communication for Fluke Connect
729CN 2M FC
Psi range, resolution -12.000 to 300.000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment For China, wireless communication for Fluke Connect
729JP 200K
kPa range, resolution -82.737 to 206.843 kPa
Comment For Japan, no wireless communication
729JP 1M
kPa range, resolution -82.73 to 1034.21 kPa
Comment For Japan, 1 MPa range, no wireless communication
729JP 2M
kPa range, resolution -82.73 to 2068.43 kPa
Comment For Japan, 2 MPa range, no wireless communication
729JP 200K FC
kPa range, resolution -82.737 to 206.843 kPa
Comment For Japan, wireless communication for Fluke Connect
729JP 1M FC
kPa range, resolution -82.73 to 1034.21 kPa
Comment For Japan, wireless communication for Fluke Connect
729JP 2M FC
kPa range, resolution -82.73 to 2068.43 kPa
Comment For Japan, wireless communication for Fluke Connect

 

Electrical specification
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
Ranges
mA measure, source and simulate 0 mA to 24 mA
Volts dc measure 0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure 1 μA
Voltage dc measurement 1 mV
Accuracy 0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
Stability 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
mA simulate external voltage requirement 12 V dc to 30 V dc
Loop compliance voltage 24 V dc @ 20 mA
mA simulate external voltage requirement 12 V dc to 30 V dc
Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution 0.01 °C (0.01 °F)
Temperature accuracy ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory)
Drive capability 1200 Ω without HART resistor, 950 Ω with internal HART resistor
Mechanical specification
Size (HxWxL) 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Weight 6.5 lbs., 2.95 kg
Ingress protection IP54
Environmental specification
Operating temperature -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control
Operating temperature with battery -10 °C to 40 °C
Battery will only charge to 40 °C
Storage temperature -40 °C to 60 °C
Operating altitude 3000 m
Storage altitude 13000 m
Wireless (729 FC only)
Radio frequency certification FCC ID: T68-FBLE IC:6627A-FBLE
Wireless radio frequency range 2412 MHz to 2462 MHz

Models: Fluke 729 Automatic Pressure Calibrator

FLK-729 30G
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, no wireless communication

FLK-729 150G
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, no wireless communication

FLK-729 300G
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, no wireless communication

FLK-729 30G FC
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, includes wireless communication for Fluke Connect

Buy it
FLK-729 150G FC
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, includes wireless communication for Fluke Connect

Buy it
FLK-729 300G FC
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, includes wireless communication for Fluke Connect

FLK-729CN 200K

Buy it
FLK-729CN 1M

Buy it
FLK-729CN 2M

Buy it
FLK-729CN 200K FC

Buy it
FLK-729CN 1M FC

Buy it
FLK-729CN 2M FC

Buy it
FLK-729PLUS 2M

Buy it
FLK-729PLUS 1M

Buy it
FLK-729PLUS 200K

Buy it

Is there a way to create a custom calibration task. ie. Make a pressure switch test that will perform a decreasing pressure test to check a PSL setpoint, and also repeat the task 3 times for repeatability. Please do not direct me to contact tech support.

Asked by: AJWS
With the Fluke 729 Automatic Pressure Calibrator you can only create a task with an increasing pressure switch test.
Answered by: FlukeCorporation
Date published: 2024-04-26

Please tell me what is the resource of the automatic pneumatic pump in the 729 model? How many cycles before the repair of an electric pump?

Asked by: Maksym
Please reach out to the relevant Fluke technical support for your country here: https://www.fluke.com/en-us/support/technical-support.
Answered by: FlukeCorporation
Date published: 2024-04-11

Where can you buy a replacement battery charger and adapters

Asked by: MikeD
Reach out to a Fluke sales expert about selecting the right product for your needs at 877-864-5880. The Fluke 729 Automatic Pressure Calibrator is compatible with the BP729, Rechargeable Li-ion Battery (part number 4817068) and Power Charger, AC/DC (part number 4878453). Other parts and accessories are available.
Answered by: FlukeCorporation
Date published: 2024-05-23

How do you calibrate a low pressure switch with the 729? You can set an increasing pressure for a high pressure switch but I can't figure out how to set a decreasing pressure setpoint.

Asked by: Gremlin
Please contact Fluke's tech support team at tech.support@fluke.com or 800-443-5853.
Answered by: FlukeCorporation
Date published: 2024-04-11

When connecting an external 750 pressure module, will the calibrator still perform the auto pump functionality if the external pressure module is of lower pressure than the pump. ex. switch test using 0-1PSI external pressure module.

Asked by: AJWS
Yes, the 729 30G calibrator can perform the auto pump functionality, but will need an external hand pump to test lower pressures if using the 729 150G or 729 300G.
Answered by: FlukeCorp
Date published: 2023-05-11
  • y_2024, m_9, d_19, h_2CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_3840953810996, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 70.98ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, , 71ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: Content Type "questions" is not supported by getReviews().;
Please enable cookies to view product reviews.