Detector resolution |
120 x 90 (10,800 pixels) |
640 x 480 (307,200 pixels) |
|
Display |
3.5 inch (8.9 cm landscape) 320 x 240 touchscreen LCD |
3.5 inch (8.9 cm landscape) 640 x 480 touchscreen LCD |
|
Field of view (FOV) |
50 °H x 38 °V |
34 °H × 24 °V |
|
Focus system |
Fixed focus |
LaserSharp® Auto Focus, auto focus and manual focus |
|
Frame rate |
9 Hz |
60 Hz or 9 Hz versions |
|
IFOV (spatial resolution) |
7.6 mRad |
0.93 mRad |
|
IR-Fusion® Technology |
AutoBlend continuous 0 % to 100 % |
4 levels: 0%, 25%, 50%, 75%, 100% |
|
Thermal Sensitivity |
60mK |
50mK |
|
Temperature measurement range |
-20 °C to +400 °C (-4 °F to +752 °F) |
-20 °C to +1000 °C (-4 °F to +1832 °F) |
|
Optional lenses |
|
Wide angle, 2x and 4x telephoto, macro |
|
Minimum focus distance |
|
With standard lens: 15 cm (6 in); with optional lenses: from 15 cm (6 in) to 1.5 m (5 ft) |
|
Wireless connectivity |
|
Fluke Connect™ app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN¹ |
|
Design |
|
Rugged, ergonomic design for one-handed use |
|
Thermal sensitivity (NETD) - best possible |
|
50mK |
|
Built-in digital camera (visible light) |
|
5 MP |
|