Select your country/region site

Fluke 87V Industrial Multimeter

Fluke 87V Industrial Multimeter is rated 4.7 out of 5 by 161.
  • y_2024, m_9, d_19, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_31, tr_130
  • loc_en_US, sid_3739292368948, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 195.12ms
  • REVIEWS, PRODUCT
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter

Key features

  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture

Product overview: Fluke 87V Industrial Multimeter

Priority Gold Instrument CarePlan

Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan

A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.

Learn more

The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.

  • Easy-access door for fast battery changes without breaking the calibration seal
  • Analog bar graph for fast changing or unstable signals
  • Large digit display with bright, two-level backlight for easier reading in low light
  • Touch Hold keeps readings on display even after removing probes

The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.

Built to highest safety standards

All the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.

Removable holster with built in test lead and probe storage for convenience

The 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.

Additional measurement features

The Fluke 87V is designed and built in the U.S. and comes with a lifetime warranty.

For a complete comparison of specifications, please visit our selection guide for digital multimeters.

  Fluke 87V Industrial Multimeter Fluke 87V MAX True-rms Digital Multimeter Fluke 289 True-RMS Data Logging Multimeter Fluke 179 True-RMS Digital Multimeter Fluke 1587 FC Insulation Multimeter
  Fluke 87V Industrial Multimeter Fluke 87V MAX True-rms Digital Multimeter Fluke 289 True-RMS Data Logging Multimeter Fluke 179 True-RMS Digital Multimeter Fluke 1587 FC Insulation Multimeter
CAT rating CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
True-rms readings
Voltage AC/DC 1000 V 1000 V 1000 V 1000 V 1000 V
Current AC/DC 10 A 10 A 10 A 10 A 400 mA
Resistance 50 MΩ 50 MΩ 500 MΩ 50 MΩ 50 MΩ
Capacitance 9,999 μF 9,999 μF 100,000 μF 9,999 μF 9,999 μF
Temperature -200 °C to 1090 °C -200 °C to 1090 °C -200 °C to 1350 °C -40 °C to 400 °C -40 °C to 537 °C
Additional
measurement
capabilities
Frequency,
continuity/diode test,
motor drive (VFD)
measurement,
duty cycle,
microamps, analog
bar graph, relative
reference
Conductance,
continuity/diode test,
duty cycle,
frequency, microamps,
motor drive (VFD)
measurement,
pulse width,
elative reference
Conductance (50ns),
duty cycle,
frequency,
continuity/diode test,
low input
impedance,
microamps,
pulse width
Continuity/diode test,
frequency,
microamps
Frequency, Pi/DAR
timed ratio tests,
continuity/diode test,
motor drive (VFD)
measurement,
microamps, relative
reference
IP rating IP 30 IP 67 IP 42 - -
Battery life 400 hours 800 hours 200 hours 200 hours 1000 hours
Drop test 3 meters 4 meters - - -
Backlit keypad No Yes No No No

What's in the box:

  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

Specifications: Fluke 87V Industrial Multimeter

Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20 °C to + 55 °C
Storage temperature –40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals CE, CSA, RCM
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument

Models: Fluke 87V Industrial Multimeter

Fluke 87V
Fluke 87V Industrial Multimeter

Buy it

Includes:

  • TL75 Test Leads (TL175 EUR)
  • AC175 Alligator Clips
  • Holster
  • 9V Battery (Installed)
  • 80BK Temperature Probe

In resistance check mode, what is the maximum output voltage? Is it >8Vdc to test an IGBT gate? Thanks

Asked by: AWSt
The Fluke 87V Industrial Multimeter's specifications can be seen at the "specifications" tab on the product page: https://www.fluke.com/en-us/product/electrical-testing/digital-multimeters/fluke-87v
Answered by: FlukeCorporation
Date published: 2024-09-05

Does the units come with calibration certs?

Asked by: Mylene
To see if your product is supported for calibration, get a quote for calibration, or schedule a service order for repair or calibration visit https://flkext.fluke.com/OA_HTML/jtflogin.jsp or to see if your instrument is supported for calibration: Email: service@fluke.com Call: 1-800-87-FLUKE (1-800-873-5853)
Answered by: FlukeCorporation
Date published: 2024-08-21

which country does fluke 87v origin from?

Asked by: Yichao
The Fluke 87V is both designed and built in the U.S.A.!
Answered by: SuperFlyEDSguy
Date published: 2024-06-05

Are you able to use the Fluke 87-v to check voltage drop?

Asked by: NormHindy
Yes, depending on what kind of voltage you will be doing (how and on what voltage). If you want a graph of a voltage drop that would depend on the speed of the drop.
Answered by: FlukeCorporation
Date published: 2024-04-14

87V万用表怎么快速有效鉴别进口和国产,真假货怎么判断

Asked by: Anonymous
  • y_2024, m_9, d_19, h_2CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_3739292368948, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 28.73ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, , 28.76ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: Content Type "questions" is not supported by getReviews().;
Please enable cookies to view product reviews.