Select your country/region site

Product selection guide: IR thermometers

Use our product selection guide to find the thermometer that fits your needs best.
 
Remove Remove
 
 
Fluke 59 MAX Infrared Thermometer
Fluke 64 Max
 
59 MAX+ Infrared Thermometer Fluke 64 MAX IR Thermometer
 
Recommended uses HVAC, general troubleshooting Short-range troubleshooting, electrical, HVAC, industrial  
What temperature range do you need to measure? -30 °C to +350 °C (-22 °F to +662 °F) -30 °C to +650 °C (-22 °F to +1202 °F)  
Will you be working from greater than 5 m (15 ft)?    
Will you be measuring objects 200 °C (400 °F), moving, uncontaminatable, energized objects or difficult to reach objects?    
Non-contact temperature range -30 °C to +350 °C (-22 °F to +662 °F) -30 °C to +650 °C (-22 °F to +1202 °F)  
Accuracy ± 1.5 °C ± 1.0 °C or ± 1.0 % of reading, whichever is greater, ± 2.0 °C or -10 °C to 0 °C, ± 3.0 °C at -30 °C to -10 °C  
Sighting Laser Laser point  
Distance to spot (D:S) 8:1 20:1  
Temperature area Internal, ambient and non-contact surface temperature Internal, ambient and non-contact surface temperature  
Form factor Pistol Pistol  
Dimensions, approximate (H x W x D) 156 x 80 x 50 mm (6.14 x 3.15 x 2 in) 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)  
Battery 1 AA Single AA Battery; 8 hours typical with lasers and backlight on  
Warranty 1 year 3 years  
Min-Max-Avg-Dif Min-Max-Avg-Dif Min-Max-Avg-Dif  
Material type adjustment (emissivity)   Preset to 0.95, adjustable by user  
High and low alarms