Detector resolution |
640 x 480 (307,200 pixels) |
256 x 192 (49,152 pixels) |
|
Display |
5.7 inch touchscreen LCD, 640 x 480 pixel resolution |
3.5 inch (8.9 cm landscape) 640 x 480 touchscreen LCD |
|
Field of view (FOV) |
34 °H × 24 °V |
28 °H x 20 °V |
|
Focus system |
LaserSharp® Auto Focus, auto focus and manual focus |
Manual focus |
|
Frame rate |
60 Hz or 9 Hz versions |
9 Hz or 27 Hz versions |
|
IFOV (spatial resolution) |
0.93 mRad |
1.91 mRad |
|
IR-Fusion® Technology |
AutoBlend continuous 0 % to 100 % |
AutoBlend continuous 0 % to 100 % |
|
Optional lenses |
Wide angle, 2x and 4x telephoto, macro |
|
|
Temperature measurement range |
-20 °C to +1000 °C (-4 °F to +1832 °F) |
-20 °C to +550 °C (-4° F to +1022 °F) |
|
Thermal Sensitivity |
50mK |
40mK |
|
Minimum focus distance |
With standard lens: 15 cm (6 in); with optional lenses: from 15 cm (6 in) to 1.5 m (5 ft) |
|
|
Wireless connectivity |
Fluke Connect™ app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN¹ |
|
|
Design |
240° rotating screen |
|
|
Thermal sensitivity (NETD) - best possible |
50mK |
|
|
Built-in digital camera (visible light) |
5 MP resolution for image and video recording |
|
|
Thermal sensitivity (NETD) |
≤ 0.05 °C at 30 °C target temp (50 mK) |
|
|